Happy House Daycare General Contractor: Ron Kalinsky 780-812-9057 email: bayrock@mcsnet.ca

 

 

 

Happy House Daycare Cold Lake

Architectural Drawings

Drawing Names

No

Revision Number

Notes

ARCHITECTURAL COVER PAGE

A-1.1

0

 

MECHANICAL EXTERIOR ELEVATIONS

A-2.1

0

 

BASEMENT FLOOR PLAN

A-3.1

1

 Pending Changes Change 2 SM underslab to 2 Plastispan

MAIN FLOOR PLAN

A-3.2

1

 Pending Changes Roxul insulation added to shear walls

2ND FLOOR PLAN

A-3.3

1

 Pending changes-south window 2nd floor to move to the East

BASEMENT FINISHES PLAN

A-4.1

1

 

MAIN FLOOR FINISHES PLAN

A-4.2

1

 

UPPER FLOOR FINISHES PLAN

A-4.3

1

 

BUILDING SECTIONS

A-5.1

0

 

STAIR RAILING SECTIONS

A-5.2

0

 

STAIR RAILING DETAILS

A-6.1

0

 

INTERIOR ELEVATIONS 1

A-6.2

0

 

ELECTRICAL INTERIOR ELEVATIONS 2

A-6.3

0

 

INTERIOR ELEVATIONS 3

A-6.4

1

 

COLUMN DETAILS

A-6.5

0

 

BARRIER FREE DETAILS

A-6.6

0

 

WINDOW SCHEDULE

A-7.1

1

 

DOOR SCHEDULE

A-7.2

1

 

 

Electrical Drawings

Drawing Names

No

Revision Number

Notes

BASEMENT FLOOR PLAN - ELETRICAL

E-1

1

 

MAIN FLOOR PLAN - ELECTRICAL

E-2

0

 

UPPER FLOOR PLAN - ELECTRICAL

E-3

1

 Pending Changes Revise to accommodate removed walls

FIRE ALARM SYSTEM & F.A. SPECS

E-4

0

 

ELECTRICAL SPECS

E-5

0

 

 

Mechanical Drawings

Drawing Names

No

Revision Number

Notes

FOUNDATION DRAINAGE LAYOUT

M-1.0

0

 

BASEMENT PLUMBING LAYOUT

M-2.1

0

 

BASEMENT IN-SLAB HEATING LAYOUT

M-2.2

0

 

MAIN FLOOR PLUMBING LAYOUT

M-2.3

0

 

UPPER FLOOR PLUMBING LAYOUT

M-2.4

0

 Pending Changes relocate sinks in classroom to accommodate removed walls

BASEMENT VENTILATION LAYOUT

M-3.1

0

Furnaces to be changed to 100,000 BTU

MAIN FLOOR VENTILATION LAYOUT

M-3.2

1

 

UPPER FLOOR VENTILATION LAYOUT

M-3.3

0

 New HRV added

SPECIFICATIONS

M-4.0

0

 

Proposed Mechanical Change Notice. July 13 2018.

Reference Mechanical Specifications  7.0:  FUR-1 and FUR-2
Delete reference to 80,000 BtuHr input gas fired furnaces and add the following specification for 100,000 BtuHr gas fired furnaces
TRANE S9X2C100U 5PSAA up-flow  2-stage condensing variable speed gas fired furnace.
Performance:
1st stage  input 65,000 BtuHr. 1st stage output 63,050 BtuHr.
2nd stage input 97,000 BtuHr. 2nd stage output 100,000 BtuHr
1st stage temperature rise  25-55  deg. F.  2nd stage temperature rise 35-65 deg. F. 96 % AFUE
Direct Drive blower . 11x10" width. variable speed motor 1 HP. Heating/Cooling  blower performance 1951 cfm at O.6" S.P medium high speed
Electrics. 120 V 1 phase 60 HZ 10.9 FLA. High velocity filter  1-20"x25" -1" thick. Vent pipe 2" round diameter outlet
Heat Exchanger -model S9X2C100 U 5P SAA Type> Fired 409 stainless steel.
un-fired 29-4C stainless steel . 20 guage fired.
Orifices -Main natural gas . quantity 5-45 drillsize. Redundant -2 stage gas valve. Pilot safety device - 120V SiNi igniter . multi-port inshot burners. number  5 .
Power connection -120 V  1 phase 60 HZ. ampacity. 14.4 amps. maximum over protection 15 amps. Pipe connections 1/2' DIAMETER SIZE .
Dimensions :  uncrated. 34"H x 21" Wx 28 3/8" D. Shipping weight. 145 net lbs. Top horizontal discharge.
combustion fan-centrifugal type direct drive 2 speeds. . Outlet air 19 11/16"x20 1/4" -3" diam.  flue inlet . 3" diam opening  air intake. Horizontal  condensing drain 1-7/8" x 7/8"  slot knockout
side return 14 3/8"x18 5/16" .

Structural Drawings

Drawing Names

No

Revision Number

Notes

STRUCTURAL FOUNDATION PLAN

S-1.1

0

 

BASEMENT PLAN

S-1.2

0

 

MAIN FLOOR PLAN

S-2.1

0

 

MAIN FLOOR JOISTS

S-2.2

0

 

UPPER FLOOR JOISTS

S-3.1

0

 

ROOF PLAN

S-4.1

0

 

BUILDING SECTIONS

S-5.1

0

 

EXTERIOR RAMP SECTION

S-5.2

0

 

EXTERIOR RAMP DETAILS

S-6.1

0

 

ICF WALL DETAIL

S-6.2

0

 

 

Miscellaneous Information

Radon Sensor

Stamped Truss Drawings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Original Submitted Drawings

Architectural

Mechanical

Electrical

Structural